| ID | From | To | Cable type | Length (m) | Status | Corrected (m) | Verified by | Date | Drawing ref | Notes |
| C0001 | PNL-AIR-2F | AHU-2F-A (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0002 | PNL-AIR-2F | AHU-2F-A (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0003 | PNL-AIR-2F | AHU-2F-A (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0004 | PNL-AIR-2F | AHU-2F-B (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0005 | PNL-AIR-2F | AHU-2F-B (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0006 | PNL-AIR-2F | AHU-2F-B (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0007 | PNL-AIR-3F | AHU-3F-AM (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0008 | PNL-AIR-3F | AHU-3F-AM (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0009 | PNL-AIR-3F | AHU-3F-AM (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0010 | PNL-CASINO-GF | AHU-CASINO-1 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0011 | PNL-CASINO-GF | AHU-CASINO-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0012 | PNL-CASINO-GF | AHU-CASINO-1 (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0013 | PNL-CASINO-GF | AHU-CASINO-2 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0014 | PNL-CASINO-GF | AHU-CASINO-2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0015 | PNL-CASINO-GF | AHU-CASINO-2 (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0016 | PNL-CASINO-GF | AHU-GF-CASINO (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0017 | PNL-CASINO-GF | AHU-GF-CASINO (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0018 | PNL-CASINO-GF | AHU-GF-CASINO (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0019 | PNL-AIR-GF | AHU-GF-LOB (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0020 | PNL-AIR-GF | AHU-GF-LOB (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0021 | PNL-AIR-GF | AHU-GF-LOB (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0022 | PNL-AIR-GF | AHU-GF-REST (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0023 | PNL-AIR-GF | AHU-GF-REST (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0024 | PNL-AIR-GF | AHU-GF-REST (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0025 | PNL-BLR-LG | BLR-1 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 10 | unverified | | | | | |
| C0026 | PNL-BLR-LG | BLR-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0027 | PNL-BLR-LG | BLR-2 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0028 | PNL-BLR-LG | BLR-2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0029 | PNL-PL-LG | CALOR-LG (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 8 | unverified | | | | | |
| C0030 | PNL-AIR-ROOF | CALOR-ROOF (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0031 | PNL-CH-PLANT-2F | CH-1 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 15 | unverified | | | | | |
| C0032 | PNL-CH-PLANT-2F | CH-1 (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0033 | PNL-CH-PLANT-2F | CH-2 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 18 | unverified | | | | | |
| C0034 | PNL-CH-PLANT-2F | CH-2 (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0035 | PNL-CH-PLANT-2F | CHW-BYP (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 10 | unverified | | | | | |
| C0036 | PNL-CH-PLANT-2F | CHW-RET-HDR (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 8 | unverified | | | | | |
| C0037 | PNL-CH-PLANT-2F | CHW-SUP-HDR (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 8 | unverified | | | | | |
| C0038 | PNL-CH-PLANT-2F | CHWP-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 10 | unverified | | | | | |
| C0039 | PNL-CH-PLANT-2F | CHWP-2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 11 | unverified | | | | | |
| C0040 | PNL-CH-PLANT-2F | CHWP-3 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0041 | PNL-CT-ROOF | CT-1 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0042 | PNL-CT-ROOF | CT-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 14 | unverified | | | | | |
| C0043 | PNL-CT-ROOF | CT-2 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0044 | PNL-CT-ROOF | CT-2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 16 | unverified | | | | | |
| C0045 | PNL-CT-ROOF | CT-COMMON (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0046 | PNL-CT-ROOF | CT-COMMON (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0047 | PNL-CT-ROOF | CW-HDR (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0048 | PNL-CH-PLANT-2F | CWP-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 13 | unverified | | | | | |
| C0049 | PNL-CH-PLANT-2F | CWP-2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 13 | unverified | | | | | |
| C0050 | PNL-CH-PLANT-2F | CWP-3 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 14 | unverified | | | | | |
| C0051 | PNL-AIR-2F | DOAS-2F (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0052 | PNL-AIR-2F | DOAS-2F (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0053 | PNL-AIR-2F | DOAS-2F (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0054 | PNL-AIR-ROOF | DOAS-RD1 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0055 | PNL-AIR-ROOF | DOAS-RD1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0056 | PNL-AIR-ROOF | DOAS-RD1 (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0057 | PNL-AIR-ROOF | DOAS-RD2 (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0058 | PNL-AIR-ROOF | DOAS-RD2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0059 | PNL-AIR-ROOF | DOAS-RD2 (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0060 | PNL-AIR-2F | EAS-GEN-2F (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0061 | PNL-AIR-3F | EAS-GEN-3F (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0062 | PNL-AIR-BSMT | EAS-GEN-BSMT (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0063 | PNL-AIR-GF | EAS-GEN-GF (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0064 | PNL-AIR-ROOF | EAS-GEN-ROOF (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0065 | PNL-AIR-2F | EAS-TOILET-2F (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0066 | PNL-AIR-3F | EAS-TOILET-3F (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0067 | PNL-AIR-BSMT | EAS-TOILET-BSMT (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0068 | PNL-AIR-GF | EAS-TOILET-GF (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0069 | PNL-PL-LG | HP-LG-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0070 | PNL-AIR-ROOF | HP-ROOF-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0071 | PNL-PL-LG | HW-HEADERS-LG (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 10 | unverified | | | | | |
| C0072 | PNL-PL-LG | HW-PUMP-LG-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0073 | PNL-PL-LG | HW-PUMP-LG-2 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0074 | PNL-AIR-ROOF | HW-PUMP-ROOF-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0075 | PNL-CASINO-GF | OZ-CASINO-1 (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0076 | PNL-AIR-2F | PAHU-2F (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 30 | unverified | | | | | |
| C0077 | PNL-AIR-2F | PAHU-2F (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 30 | unverified | | | | | |
| C0078 | PNL-AIR-2F | PAHU-2F (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 30 | unverified | | | | | |
| C0079 | PNL-AIR-BSMT | PAHU-BSMT (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0080 | PNL-AIR-BSMT | PAHU-BSMT (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0081 | PNL-AIR-BSMT | PAHU-BSMT (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0082 | PNL-AIR-ROOF | PAHU-ROOF (BMS Contractor) | 4C × 1.5 mm² shielded FRLS (BMS signal — sensors) | 12 | unverified | | | | | |
| C0083 | PNL-AIR-ROOF | PAHU-ROOF (Equipment Supplier) | 4C × 1.5 mm² FRLS (equipment aux contacts — status/HOA/trip) | 12 | unverified | | | | | |
| C0084 | PNL-AIR-ROOF | PAHU-ROOF (ME Contractor) | 4C × 1.5 mm² FRLS (ME-supplied valves/dampers — status + control) | 12 | unverified | | | | | |
| C0085 | PNL-CH-PLANT-2F | CH-1 (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0086 | PNL-CH-PLANT-2F | CH-2 (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0087 | PNL-CH-PLANT-2F | BTU-CHW-MAIN (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0088 | PNL-PM-LG | PM-MAIN-LG (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0089 | PNL-CH-PLANT-2F | PM-CHILLER (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0090 | PNL-CT-ROOF | PM-COOLING (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0091 | PNL-AIR-2F | PM-AIR-2F (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 30 | unverified | | | | | |
| C0092 | PNL-AIR-GF | PM-AIR-GF (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 30 | unverified | | | | | |
| C0093 | PNL-CASINO-GF | PM-CASINO (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 30 | unverified | | | | | |
| C0094 | PNL-BLR-LG | PM-BOILER (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0095 | PNL-PL-LG | PM-PLUMB (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| C0096 | PNL-PL-LG | PM-FIREPMP (Network) | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) | 12 | unverified | | | | | |
| T0097 | BMS Server Room (head-end) | All BMS panels at 2nd Floor | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) — riser fiber + Cat6 trunk | 80 | unverified | | | | | |
| T0098 | BMS Server Room (head-end) | All BMS panels at Basement | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) — riser fiber + Cat6 trunk | 80 | unverified | | | | | |
| T0099 | BMS Server Room (head-end) | All BMS panels at Ground | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) — riser fiber + Cat6 trunk | 80 | unverified | | | | | |
| T0100 | BMS Server Room (head-end) | All BMS panels at Lower Ground | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) — riser fiber + Cat6 trunk | 80 | unverified | | | | | |
| T0101 | BMS Server Room (head-end) | All BMS panels at Roofdeck | Cat6 4P × 23 AWG U/UTP, FRLS jacket (BACnet/IP) — riser fiber + Cat6 trunk | 80 | unverified | | | | | |
| T0102 | BMS Server Room (head-end) | All BMS panel controllers (MS/TP daisy-chain or branched) | BACnet MS/TP shielded twisted-pair trunk, 1pr × 22 AWG low-cap | 330 | unverified | | | | | |
| P0103 | Local panelboard / EE-supplied feeder | PNL-AIR-2F — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0104 | Local panelboard / EE-supplied feeder | PNL-AIR-3F — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0105 | Local panelboard / EE-supplied feeder | PNL-AIR-BSMT — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0106 | Local panelboard / EE-supplied feeder | PNL-AIR-GF — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0107 | Local panelboard / EE-supplied feeder | PNL-AIR-ROOF — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 35 | unverified | | | | | |
| P0108 | Local panelboard / EE-supplied feeder | PNL-BLR-LG — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0109 | Local panelboard / EE-supplied feeder | PNL-CASINO-GF — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0110 | Local panelboard / EE-supplied feeder | PNL-CH-PLANT-2F — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0111 | Local panelboard / EE-supplied feeder | PNL-CT-ROOF — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 35 | unverified | | | | | |
| P0112 | Local panelboard / EE-supplied feeder | PNL-PL-LG — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |
| P0113 | Local panelboard / EE-supplied feeder | PNL-PM-LG — BMS panel 240V power feed | 3C × 2.5 mm² FRLS (240V single-phase BMS panel power feed) | 18 | unverified | | | | | |